Model 1380
SECTION 08361 SECTIONAL DOORS - MEDIUM DUTY 1-3/8" INSULATED STEEL PART 1 -
GENERAL
1.01 SUMMARY
A. Sectional doors shall be Model 1380 as manufactured by Amarr Garage Doors, 5931
Grassy Creek, Winston-Salem, NC 27105. Telephone: (336) 744-5100. Fax: (336) 744-0895.
1. Mounting to be interior face mounted on a prepared surface.
2. Doors shall be insulated steel sectional overhead type. Each door includes sections,
brackets, tracks, counterbalance mechanisms, and hardware to suit the opening and headroom
available.
B. Operation: Manual pushup.
SELECT PARAGRAPH ABOVE FOR MANUALLY OPERATED DOORS OR PARAGRAPH BELOW FOR ELECTRICALLY
OPERATED DOORS.
C. Operation: Electric operator.
1.02 RELATED WORK SPECIFIED ELSEWHERE
A. Miscellaneous or structural steel: Division 5 Metals.
RETAIN FOLLOWING PARAGRAPH IF DOORS ARE TO BE FIELD PAINTED.
B. Field painting: Section 09900 Painting.
RETAIN FOLLOWING PARAGRAPH IF DOORS ARE TO HAVE ELECTRIC OPERATORS.
C. Electrical work in conjunction with electric operators: Division 16 Electrical.
1.03 PERFORMANCE AND DESIGN REQUIREMENTS
A. Provide sectional door assemblies designed to withstand the following loading
conditions:
IF PROJECT CONDITIONS REQUIRE HIGHER WIND LOADING, REVISE FOLLOWING PARAGRAPH
ACCORDINGLY. CONSULT AMARR FOR SPECIFIC WIND LOAD APPLICATIONS
1. Wind loading pressure of 15.2 pounds per square foot (equivalent to 78 miles per
hour).
B. Energy Values:
1. U-value: 0.17
2. R-value: 5.73
1.04 SUBMITTALS
A. Product Data: Manufacturer's product literature marked to indicate products being
provided.
RETAIN FOLLOWING PARAGRAPH IF DOORS ARE TO HAVE ELECTRIC OPERATORS.
1. For doors with electric operators, submit electrical characteristics of operators.
B. Shop Drawings: Submit dimensioned prints showing critical dimensions, attachment
conditions, and relation to adjacent work.
1.05 WARRANTY
A. Amarr Company warrants, to the original purchaser, its products to be free from
defects in material and workmanship for a period of (1) year from the date of purchase,
when installed by qualified installation personnel in accordance with instructions from
the manufacturer.
B. Additional warranties are described in Part 2 - Products.
PART 2 - PRODUCTS
2.01 DOOR SECTIONS
A. Steel sections shall be 1-3/8" thick sandwich construction consisting of
exterior and interior steel skins laminated to an expanded polystyrene (EPS) foam core
with a urethane adhesive. Both steel skins to be separated by PRO-Bond, a continuous
silicone seal that forms a thermal break. Steel skins shall be roll formed commercial
quality hot-dipped galvanized (ASTM A 653-94) and Zinc phosphate pre-treated with primer
and baked-on polyester top coat. Door sections shall be constructed of 27 gauge
(0.016" min.) exterior and interior skins. Both skins to have stucco embossed
texture. The exterior steel skin has 0.41" minor ribs on 4" or 5" centers.
20 gauge steel end stiles shall be galvanized, primed, finish painted and engineered for
easy hardware attachment through prepunched extruded holes. 18 gauge galvanized, primed
steel support plates are located under each hinge location, and are prepunched for hinge
attachment. Section joint to form weathertight tongue and groove joint. Polypropylene
Wear-Seal attached between each tongue and groove joint to diminish normal wear and tear
on sections and to form a second thermal break. Galvanized steel step plate/lift handle
provided on inside and outside of bottom section.
B. Finish: The door exterior and interior is prepainted steel consisting of a phosphate
coating over hot-dipped galvanization applied to the base metal. A 0.2- 0.3 mil baked-on
prime coat is applied and then a 0.8 mil baked-on polyester top-coat is applied for
ultimate rust protection. The paint finish carries a 10-year warranty against film
integrity (peeling) and against color performance (fading) and chalking. The inside of the
exterior and interior skins is finished with a 0.2-0.3 mil primer.
C. Insulation: 1-3/8" thick CFC-free expanded polystyrene (EPS) laminated to the
inside of both interior and exterior steel skins with a special urethane adhesive.
Supported by a one- year warranty against delamination of insulation from steel.
D. Weatherstripping:
1. Provide 3-1/2" U-shaped vinyl bottom seal in a full-length 0.050" aluminum
retainer attached to the bottom section.
ABOVE IS STANDARD. BELOW IS OPTIONAL.
2. Provide perimeter seal for header and jambs.
2.02 TRACK
A. Galvanized steel track shall be 2" or 3" as required. Continuous reverse
angle mounting is standard for steel jambs. Bracket mounting is standard for wood jambs.
Vertical tracks to be minimum 17 gauge galvanized steel, inclined through the use of
adjustable brackets to assure weathertight closure at the jambs. Horizontal tracks to be
minimum 16 gauge galvanized steel, reinforced with 13 gauge galvanized steel angles as
required by door size and weight.
B. Track Type:
SELECT APPLICABLE TRACK TYPE FROM THE FOLLOWING.
1. Standard Lift
2. Low Headroom
3. Vertical-Lift
4. High-Lift
5. Follow the Roofline
2.03 HARDWARE
A. Hardware includes minimum 14 gauge galvanized hinges and brackets. All rollers to
have 10-ball bearings with casehardened inner and outer races. Sliding end stile locking
device with spring-loaded bolt for inside operation only. Galvanized struts (truss bars)
supplied on all doors 14'3" and wider to prevent deflection no more than 1/120 of the
spanned width when in the open position.
2.04 SPRING COUNTERBALANCE
A. Torsion springs for door counter-balance are mounted on a continuous cross header
shaft. Springs are oil tempered, helical wound and custom computed for each door. Cable
drums are die cast aluminum. Galvanized lift cable will provide minimum safety factor of
five to one. Springs to comply with NAGDM/ANSI 102-1988.
2.05 LOCK
A. Provide interior sliding end stile lock with hole to receive padlock.
SELECT ABOVE WHICH IS STANDARD, OR BELOW WHICH IS OPTIONAL.
B. Provide 5-pin cylinder lock with interior lock bar and outside key.
2.06 WINDOW LITES
WINDOW LITES ARE OPTIONAL. SELECT FROM THE FOLLOWING.
A. Framed lite 24" x 4" clear acrylic sheet.
B. Framed lite 24" x 12" SSB.
C. Framed lite 24" x 12" insulating glass.
D. Frame: Screw together of PVC construction.
2.07 SPRINGS
A. Provide standard 10,000 cycle torsion springs.
HIGH CYCLE SPRINGS ARE OPTIONAL. CONSULT AMARR. IF HIGH CYCLE SPRINGS ARE APPROPRIATE,
SELECT ONE OF THE FOLLOWING.
B. Provide 25,000 cycle torsion springs.
C. Provide 50,000 cycle torsion springs.
D. Provide 100,000 cycle torsion springs.
IF EXHAUST PORTS ARE REQUIRED, RETAIN THE FOLLOWING.
2.08 EXHAUST PORT
A. Provide exhaust ports for the release of vehicle emissions. Tubes to conduct
emissions from vehicles to exhaust ports are not included.
RETAIN FOLLOWING PARAGRAPH IF DOORS ARE TO HAVE ELECTRIC OPERATORS.
2.09 ELECTRIC OPERATORS
A. Provide Link electric operators for electrically operated doors. Operator type and
motor size shall be selected by Amarr to suit door application and size.
IF DOORS ARE TO HAVE ELECTRIC OPERATORS WITH SAFETY REVERSING EDGES, RETAIN THE
FOLLOWING PARAGRAPHS.
2.10 REVERSING EDGES
A. Electric motor operated doors shall be equipped with electrically activated
reversing edges (not pneumatic) as manufactured by Miller Edge, Inc., Concordville, PA
19331. The switching function shall be performed by two flexible Alumaglas contact strips
separated by a soft perforated foam cushion. Reversing edges shall be activated by 5 psi
(nominal) pressure along entire span of door opening and provide mechanical stops.
B. OPTIONAL: For optimum protection, Sensing Edge shall be of four wire electrical
configuration so that loss of continuity in the circuit will cause a closing door to open
and prevent an open door from closing.
PART 3 - EXECUTION
3.01 EXAMINATION
A. Verify that dimensions are correct and substrate is in proper condition for
installation of sectional doors. Do not proceed with installation until unsatisfactory
conditions have been corrected.
3.02 INSTALLATION
A. Installation shall be by qualified dealer in accordance with Amarr's installation
instructions and local building codes.
END OF SECTION
Model 1380 Width Max # Windows through 8'2" 2 8'3"-12'2" 3
12'3"-16'2" 4
Height* Sections High through 8'1" 4 8'2"-10'1" 5 10'7"-12'1"
6 12'4"-14'1" 7 Most odd heights available. Max size = 14'2" x 14'1",
16'2" x 12'1".